Commercial use

Sectional garage doors

24 Vdc

Up to 22 ㎡

Integrated device that guarantees maximum precision during the automation manoeuvring steps

Intelligent power control system that allows obtaining dynamic data through a precise calculation of the thrust. The system is able to locate any critical points and adjust the torque accordingly in relation to actual requirements and according to measured performance

64 transmitters storable inside the receiver

Standby power consumption complies with European regulation (EU) 2023/826

JM.4SE

24 Vdc | intensive use

24 Vdc gear motor for intensive use with built-in control unit and encoder | Standby power consumption complies with European regulation (EU) 2023/826 | Adjustable stroke with one mechanical stop included in the belt tracks and two in the chain tracks | Anti-crushing system with amperometric detection | Advanced electronics with display and LED courtesy light | The encoder device guarantees maximum safety and precision during door movement | STC System device that allows torque delivery to be managed in relation to the door position, ensuring maximum safety | Quick hooking system for connecting the arm to the door plate

Rail not included

Use commercial
Power supply 230 Vac (50-60Hz)
Motor supply 24 Vdc
Max absorbed current 1.5 A
Thrust 1200 N
Opening speed 4.5 ÷ 8.9 m/min
Duty cycle intensive use
Protection level IP40
Built-in control unit
Integrated receiver
Encoder
Limit switch electronic with encoder
Operating temperature -20°C /+50°C
Door surface area 22 ㎡/max
Weight 6.8 kg
N. motors per pallet 50

CP.J4-SE

APPLICATION

1 actuator series JM.3SE, JM.4SE

CONTROL UNIT POWER SUPPLY

230 Vac - 50/60 Hz

MOTORS POWER SUPPLY

24 Vdc / 8.5 A

MAIN FUNCTIONS

Integrated LCD display | Integrated 433.92 MHz radio receiver with 64 codes and 3 radio encodings (Advanced Rolling Code, Rolling Code, Fixed Code) | Integrated ESA+ device for energy saving | Fixed terminal blocks | Automatic and semi-automatic operating logic | Step-by-step inputs, open, close, stop, photocell | Input for N.C. or 8K2 sensitive edge | Output configurable as gate open indicator light, courtesy light, second radio channel or zone light | Output for flashing light connection | Photocell test | Operating parameter autoset | Electronic torque adjustment with automatic calculation for each point of the stroke (STC SYSTEM) | Anti-crushing safety device with amperometric detection and encoder management | Option to set slow start for 2 seconds (SOFT START) | Adjustable slowdowns | Number of operations | Programming access password | Maintenance warning | Standby power consumption complies with European regulation (EU) 2023/826

Technical Drawing JM.4SE
Terminal Diagram JM.4SE