CP.BULL-REV
Control unit that manages the encoder for maximum precision during the automation manoeuvring steps
This function automatically adjusts the operational parameters for simplifying the system’s installation and testing operations
This is used to set the number of cycles after which the required maintenance of the system is signaled
This allows a code to be entered for protection of the control unit programming, to prevent access to menus and modification of parameters
64 transmitters storable inside the receiver
CP.BULL-REV
APPLICATION
1 actuator for sliding gates, series BULL HE
CONTROL UNIT POWER SUPPLY
230 Vac - 50/60 Hz
MOTORS POWER SUPPLY
230 Vac / 1000 W
MAIN FUNCTIONS
Integrated LCD display | Integrated 433.92 MHz 64-codes radio receiver with 3 encoding systems (Advanced Rolling Code, Rolling Code, Fixed Code) | Removable terminal boards | Automatic, semi-automatic and Deadman logic | Encoder input to detect obstacles | Motor limit switch inputs | Open, close, pedestrian, step by step and stop inputs | Photocell input (PHOT O) programmable as active in opening-closing and in closing phases | Photocell input (PHOT C) programmable as active in opening-closing phases | Input for N.C or 8K2 sensitive edge | Output for configuration as gate open indicator, second radio channel or courtesy light | Output for connecting the flashing light | Photocell testing output | Autoset of operating parameters | Electronic motor torque adjustment | Adjustable slow-down systems | Electronic braking guarantees a precise stop even with heavy doors | Advantouch system to configure parameters and manage radio transmitters | Number of manoeuvres | Programming access password | Maintenance warning